Digital Air Data Ramp Tester - RVSM
Basic figures include non linearity, hystersis, and repeatability. Regular use of the "Zero" key for the differential measurements assumed. All values are +1 - 1 digit.
Barometric Range: 11.6 PSI - 16.7 PSI Absolute +/- 0.002 PSI
23.405" Hg - 34.098 1-Hg
All Other Ranges: +/- 0.02% of reading +/- 0.01% F.S.
These figures include linearity, hystersis and repeatability,
and temperature effects above 50 Deg. F to 86 Deg. F
Stability over 12 months 100 ppm / 01%
The AD473 Air Data Test Set is calibrated against precision pressure calibration equipment which is traceable to the National Institute of Standards and Technology (NIST.) It is recommended that the unit be recertified at least once every 12 calendar months.
Case Color: Choice of 2 colors (Yellow or Green)
Power: 28V DC, 80-250V AC, 45-410 Hz
Outputs: RS232, Analog, IEEE 488/Data Logging/Storage & Printer via
Serial communications Port
Data Logging, scratch pad memory stored and/or printed via the RS 232 Serial Communications port with 23 measurement parameters or pressure or vacuum.
Nav-Aids USA, Inc., 9835 Clear-Vue Court, Mokena, Illinois, 60477 United States. Phone: 708-478-4150