To use the tool, a current loop sensor is clamped to the positive lead of the charger/analyzer. The negative quick-connect probe is attached to the negative terminal of the battery, and the positive quick-connect probes are attached to each cell in sequence for nickel-cadmium batteries, or in the case of lead-acid batteries, to the positive terminal
In operation, the unit automatically scans the complete series of nickel-cadmium cells and the operator can check on the process at any time. The display presents each cell voltage and the battery current and voltage. If a fault occurs, a warning light flashes and the instrument emits an audible tone.